Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 4 de 4
1.
Circ Cardiovasc Imaging ; 17(4): e016104, 2024 Apr.
Article En | MEDLINE | ID: mdl-38567518

BACKGROUND: The Fontan operation is a palliative technique for patients born with single ventricle heart disease. The superior vena cava (SVC), inferior vena cava (IVC), and hepatic veins are connected to the pulmonary arteries in a total cavopulmonary connection by an extracardiac conduit or a lateral tunnel connection. A balanced hepatic flow distribution (HFD) to both lungs is essential to prevent pulmonary arteriovenous malformations and cyanosis. HFD is highly dependent on the local hemodynamics. The effect of age-related changes in caval inflows on HFD was evaluated using cardiac magnetic resonance data and patient-specific computational fluid dynamics modeling. METHODS: SVC and IVC flow from 414 patients with Fontan were collected to establish a relationship between SVC:IVC flow ratio and age. Computational fluid dynamics modeling was performed in 60 (30 extracardiac and 30 lateral tunnel) patient models to quantify the HFD that corresponded to patient ages of 3, 8, and 15 years, respectively. RESULTS: SVC:IVC flow ratio inverted at ≈8 years of age, indicating a clear shift to lower body flow predominance. Our data showed that variation of HFD in response to age-related changes in caval inflows (SVC:IVC, 2, 1, and 0.5 corresponded to ages, 3, 8, and 15+, respectively) was not significant for extracardiac but statistically significant for lateral tunnel cohorts. For all 3 caval inflow ratios, a positive correlation existed between the IVC flow distribution to both the lungs and the HFD. However, as the SVC:IVC ratio changed from 2 to 0.5 (age, 3-15+) years, the correlation's strength decreased from 0.87 to 0.64, due to potential flow perturbation as IVC flow momentum increased. CONCLUSIONS: Our analysis provided quantitative insights into the impact of the changing caval inflows on Fontan's long-term HFD, highlighting the importance of SVC:IVC variations over time on Fontan's long-term hemodynamics. These findings broaden our understanding of Fontan hemodynamics and patient outcomes.


Fontan Procedure , Heart Defects, Congenital , Humans , Child, Preschool , Child , Adolescent , Vena Cava, Superior/diagnostic imaging , Vena Cava, Superior/surgery , Vena Cava, Superior/physiology , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/surgery , Liver/diagnostic imaging , Hemodynamics/physiology , Vena Cava, Inferior/diagnostic imaging , Vena Cava, Inferior/surgery , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery
2.
medRxiv ; 2023 Aug 08.
Article En | MEDLINE | ID: mdl-37609263

Stroke remains a leading cause of complications and mortality in heart failure patients treated with LVAD circulatory support. Hemodynamics plays a central role in affecting risk and etiology of stroke during LVAD support. Yet, detailed quantitative assessment of hemodynamic variables and their relation to stroke outcomes in patients with an implanted LVAD remains a challenge. We present an in silico hemodynamics analysis in a set of 12 patients on LVAD support; 6 with reported stroke outcomes and 6 without. We conducted patient-specific hemodynamics simulations for models with the LVAD outflow graft reconstructed from cardiac-gated CT images. A pre-implantation baseline flow model was virtually generated for each case by removing the LVAD outflow graft and driving flow from the aortic root. Hemodynamics was characterized using quantitative descriptors for helical flow, vortex generation, and wall shear stress. Our analysis showed higher average values for descriptors of positive helical flow, vortex generation, and wall shear stress, across the 6 cases with stroke outcomes on LVAD support, when compared with cases without stroke. When the descriptors for LVAD-driven flow were compared against estimated baseline flow pre-implantation, extent of positive helicity was higher, and vorticity and wall shear were lower in cases with stroke compared to those without. The study suggests that quantitative analysis of hemodynamics after LVAD implantation; and hemodynamic alterations from a pre-implant flow scenario, can potentially reveal hidden information linked to stroke outcomes during LVAD support. This has broad implications on understanding stroke etiology, LVAD treatment planning, surgical optimization, and efficacy assessment.

3.
Cardiovasc Eng Technol ; 14(4): 560-576, 2023 08.
Article En | MEDLINE | ID: mdl-37340092

Left ventricular assist device (LVAD) provides mechanical circulatory support for patients with advanced heart failure. Treatment using LVAD is commonly associated with complications such as stroke and gastro-intestinal bleeding. These complications are intimately related to the state of hemodynamics in the aorta, driven by a jet flow from the LVAD outflow graft that impinges into the aorta wall. Here we conduct a systematic analyses of hemodynamics driven by an LVAD with a specific focus on viscous energy transport and dissipation. We conduct a complementary set of analysis using idealized cylindrical tubes with diameter equivalent to common carotid artery and aorta, and a patient-specific model of 27 different LVAD configurations. Results from our analysis demonstrate how energy dissipation is governed by key parameters such as frequency and pulsation, wall elasticity, and LVAD outflow graft surgical anastomosis. We find that frequency, pulsation, and surgical angles have a dominant effect, while wall elasticity has a weaker effect, in determining the state of energy dissipation. For the patient-specific scenario, we also find that energy dissipation is higher in the aortic arch and lower in the abdominal aorta, when compared to the baseline flow without an LVAD. This further illustrates the key hemodynamic role played by the LVAD outflow jet impingement, and subsequent aortic hemodynamics during LVAD operation.


Heart Failure , Heart-Assist Devices , Humans , Aorta, Thoracic/surgery , Hemodynamics , Heart Failure/surgery , Aorta, Abdominal
4.
Ann Biomed Eng ; 51(6): 1226-1243, 2023 Jun.
Article En | MEDLINE | ID: mdl-36705866

Left ventricular assist devices (LVADs) comprise a primary treatment choice for advanced heart failure patients. Treatment with LVAD is commonly associated with complications like stroke and gastro-intestinal (GI) bleeding, which adversely impacts treatment outcomes, and causes fatalities. The etiology and mechanisms of these complications can be linked to the fact that LVAD outflow jet leads to an altered state of hemodynamics in the aorta as compared to baseline flow driven by aortic jet during ventricular systole. Here, we present a framework for quantitative assessment of aortic hemodynamics in LVAD flows realistic human vasculature, with a focus on quantifying the differences between flow driven by LVAD jet and the physiological aortic jet when no LVAD is present. We model hemodynamics in the aortic arch proximal to the LVAD outflow graft, as well as in the abdominal aorta away from the LVAD region. We characterize hemodynamics using quantitative descriptors of flow velocity, stasis, helicity, vorticity and mixing, and wall shear stress. These are used on a set of 27 LVAD scenarios obtained by parametrically varying LVAD outflow graft anastomosis angles, and LVAD flow pulse modulation. Computed descriptors for each of these scenarios are compared against the baseline flow, and a detailed quantitative characterization of the altered state of hemodynamics due to LVAD operation (when compared to baseline aortic flow) is compiled. These are interpreted using a conceptual model for LVAD flow that distinguishes between flow originating from the LVAD outflow jet (and its impingement on the aorta wall), and flow originating from aortic jet during aortic valve opening in normal physiological state.


Heart Failure , Heart-Assist Devices , Humans , Heart-Assist Devices/adverse effects , Models, Cardiovascular , Aorta , Aorta, Thoracic/physiology , Hemodynamics
...